Vue de la page 625
17-30 DS785UM1
Copyright 2007 Cirrus Logic
IrDA
EP93xx User’s Guide
1
7
1
7
17
BRAB: Buffered Receiver Abort.
0 - No abort was detected in the last frame.
1 - The last frame was terminated with an abort condition.
IrTR0
Address:
0x808B_0024 - Read Only
Default:
0x0000_0000
Definition:
IrDA Test Register 0. This register indicates the received byte count.
Bit Descriptions:
RSVD: Reserved. Unknown During Read.
BC: Byte Count. The total number of valid bytes read by the
receiver.
IrDMACR
Address:
0x808B_0028 - Read/Write
Default:
0x0000_0000
Definition:
IrDA DMA Control Register.
Bit Descriptions:
RSVD: Reserved. Unknown During Read.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543210
RSVD BC
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543 2 1 0
RSVD DMAERR TXDMAE RXDMAE