Cirrus-logic EP93xx Manuel d'utilisateur Page 639

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 824
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 638
DS785UM1 18-5
Copyright 2007 Cirrus Logic
Timers
EP93xx User’s Guide
1
8
1
8
Address:
Timer3 - 0x8081_0084 - Read Only
Reset Value:
0x0000_0000
Definition:
The Value location gives the current value of the timer. When the Timer Load
register is written to, the Value register is also updated with this Load value.
Bit Descriptions:
Value: Current value of the timer.
Timer1Clear,
Timer2Clear,
Timer3Clear
Address:
Timer1 - 0x8081_000C - Write Only
Timer2 - 0x8081_002C - Write Only
Timer3 - 0x8081_008C - Write Only
Reset Value:
Not defined.
Definition:
Writing any value to the Clear location clears an interrupt generated by the
timer.
Bit Descriptions:
RSVD: This register has no readable bits. It is just a write trigger.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543210
RSVD
Vue de la page 638