Cirrus-logic CS4353 Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
10 DS803F3
CS4353
DIGITAL INTERFACE CHARACTERISTICS
Test conditions (unless otherwise specified): AGND = DGND = CPGND = 0 V; all voltages with respect to ground.
INTERNAL POWER-ON RESET THRESHOLD VOLTAGES
Test conditions (unless otherwise specified): AGND = DGND = CPGND = 0 V; all voltages with respect to ground.
Figure 2. Power-on Reset Threshold Sequence
Parameters Symbol Min Typ Max Units
High-Level Input Voltage 1.2 V <VL 3.3 V
0.9 V VL 1.2 V
V
IH
V
IH
0.7xVL
0.9xVL
-
-
-
-
V
V
Low-Level Input Voltage 1.2 V <VL 3.3 V
0.9 V VL 1.2 V
V
IL
V
IL
-
-
-
-
0.3xVL
0.1xVL
V
V
Input Leakage Current I
in
--±10A
Input Capacitance - 8 - pF
Parameters Symbol Min Typ Max Units
Internal Reset Asserted at Power-On
V
on1
-1.00- V
Internal Reset Released at Power-On
V
on2
-2.36- V
Internal Reset Asserted at Power-Off
V
off
-2.22- V
VCP
V
on2
V
on1
V
off
DGND
HI
LO
No Power
reset
undefined
reset
active
DAC
Ready
reset
active
reset
(internal)