CS5463
32 DS678F3
6.1.17 Reactive Power Register ( Q
Trig
)
Address: 24
The Reactive Power (Q
Trig
) is calculated using trigonometric identities. (See Section 4.3 Power Measurements
on page 14). The value is represented in unsigned notation and in the range of 0
S 1.0, with the binary point
to the right of the MSB.
6.1.18 Power Factor Register ( PF )
Address: 25
Power Factor is calculated by dividing the Active (Real) Power by Apparent Power. The value is represented in
two's complement notation and in the range of -1.0
PF 1.0, with the binary point to the right of the MSB.
6.1.19 Apparent Power Register ( S )
Address: 27
Apparent power (S) is the product of the V
RMS
and I
RMS
, The value is represented in unsigned notation and in
the range of 0
S 1.0, with the binary point to the right of the MSB.
MSB LSB
0
2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
2
-7
.....
2
-17
2
-18
2
-19
2
-20
2
-21
2
-22
2
-23
MSB LSB
-(2
0
)2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
2
-7
.....
2
-17
2
-18
2
-19
2
-20
2
-21
2
-22
2
-23
MSB LSB
0
2
-1
2
-2
2
-3
2
-4
2
-5
2
-6
2
-7
.....
2
-17
2
-18
2
-19
2
-20
2
-21
2
-22
2
-23
Vue de la page 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 45 46

Commentaires sur ces manuels

Pas de commentaire