Cirrus-logic CS4392 Manuel d'utilisateur Page 37

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 36
CS4392
DS459PP3 37
RECOMMENDED OPERATING SPECIFICATIONS (AGND = 0V; all voltages with respect
to AGND.)
ABSOLUTE MAXIMUM RATINGS (AGND = 0 V; all voltages with respect to ground.)
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation is
not guaranteed at these extremes.
Parameters Symbol Min Typ Max Units
DC Power Supply VA
VL
4.75
1.8
5.0
-
5.25
VA
V
V
Parameters Symbol Min Max Units
DC Power Supply VA
VL
-0.3
-0.3
6.0
VA
V
V
Input Current, Any Pin Except Supplies I
in
10mA
Digital Input Voltage V
IND
-0.3 VL+0.4 V
Ambient Operating Temperature (power applied) T
A
-55 125 °C
Storage Temperature T
stg
-65 150 °C
Vue de la page 36
1 2 ... 32 33 34 35 36 37 38 39 40

Commentaires sur ces manuels

Pas de commentaire