Cirrus-logic AN366 Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 50
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
AN366
AN366REV2 11
Figure 6. Phase Compensation and Phase Offset Error
4.2.2 No Load Power Compensation
There are two power compensations in the CS5480/84/90: active and reactive power offset. When no load
is applied, the average active power register, P
AVG
, and average reactive power register, Q
AVG
, may have
offsets. To remove any remaining active or reactive power, it is necessary to perform the following compen-
sation:
- Apply full scale voltage source
- Apply no load to the current channel(s)
- Start continuous conversion
- Read P
AVG
and Q
AVG
register
- Write -P
AVG
and -Q
AVG
to P
OFF
and Q
OFF
, respectively
Before Calibration V is delayed from I
Delay added to I
8 .99 º @ 50 Hz
10.79 º @ 60Hz
4.5º @ 50Hz
5.4º @ 60Hz
-4.5º @ 50Hz
-5.4º @ 60Hz
-8.99º @ 50Hz
-10 .79 º @ 60 H z
Before Calibration I is delayed from V
Delay added to V
Set CPCC = 11 of 2OW R on V
+ FPCC provides adjustment
Set CPCC = 10 of 1OW R on V
+ FPCC provides adjustment
Clear CPCC = 00
+ FPCC provides adjustment
Set CPCC = 01 of 1OWR on I
+ FPCC provides adjustment
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 49 50

Commentaires sur ces manuels

Pas de commentaire