20 AN379REV2
Step 22) Layout
Basics for any power layout:
Keep power traces as short as possible.
Keep the controller away from power components and traces if possible. Keep sensitive traces (all sense
inputs) away from high dv/dt traces such as FET drain and FET gate drive.
Decouple the capacitor directly at the VDD pin of the CS1680 to GND.
Run sense traces, especially current sense, away from power-carrying traces characterized by high dv/dt
(fast rise/fall times) traces such as sources and drains of FETs Q
BST
, Q
CLAMP
, and Q
BUCK
.
Further details are available in application note AN346 CS150x and CS160x PCB Layout Guidelines.