CDB5480U
CDB5480U Engineering Board and GUI Software
Features
Standalone Power Meter Application
Voltage and Current Interfaces
Low- and High-voltage Sensor Connections
Adaptable Sensor Filters Onboard
USB Communication with PC
UART/SPI Isolated Communication
Onboard C8051F342 Microcontroller
Single Supply Operation from USB or an External +5V DC
Supply
Onboard DC-DC Converter and Regulator
LCD Power Monitor Display
LabWindows
®
/CVI
®
GUI Software
Full Register Setup & Chip Control
Simplified Register Access
Quick Calibration Control
FFT Analysis
Time Domain Analysis
Noise Histogram Analysis
Voltage Reference Access
General Description
The CDB5480U is an extensive tool designed to evaluate the
functionality and performance of the Cirrus Logic CS5480
power/energy measurement device.
Multiple analog input connection options, configuration input
filters, direct and isolated digital interfaces, multiple power
supply options, an onboard programmable micro-controller, and
visual LEDs with an LCD panel make the board a flexible and
powerful customer development tool for various power/energy
measurement applications.
The GUI software provides easy and complete access to the
onboard CS5480 device. In addition, it includes the function of
raw ADC data collection with time domain, frequency domain,
and histogram analysis.
Schematics in the PADS™ PowerLogic™ format are available
for download at http://www.cirrus.com/en/support
.
ORDERING INFORMATION
CDB5480U-Z Evaluation Board
APR’12
DS893DB5
Vue de la page 0
1 2 3 4 5 6 ... 46 47

Résumé du contenu

Page 1 - CDB5480U

Copyright  Cirrus Logic, Inc. 2012(All Rights Reserved)Cirrus Logic, Inc.http://www.cirrus.comCDB5480UCDB5480U Engineering Board and GUI SoftwareFeat

Page 2

CDB5480U10 DS893DB51.5 Power Supply SelectionTable 4 illustrates the power supply connections on the evaluation board. The positive analog (VDDA) fort

Page 3

CDB5480UDS893DB5 111.6 Typical Sensor ConnectionsThe CDB5480U evaluation board provides connections directly to several types of sensors. Flexibleonbo

Page 4

CDB5480U12 DS893DB51.6.2 Current Transformer Power Meter ExampleA slightly more expensive option is to use a current transformer (CT) to connect the A

Page 5

CDB5480UDS893DB5 131.6.3 Rogowski Coil Power Meter ExampleRogowski coil power meter can be easily connected to the CDB5480U evaluation board. Figure 8

Page 6

CDB5480U14 DS893DB51.7 Standalone Meter ApplicationThe CDB5480U evaluation board provides a standalone power meter using the CS5480, MCU, and LCD.The

Page 7

CDB5480UDS893DB5 152. SOFTWAREThe evaluation board comes with software and a USB cable to link the evaluation board to the PC. Theevaluation software

Page 8

CDB5480U16 DS893DB52.3 Start-up WindowWhen the software is launched, the start-up window will appear. This window contains informationconcerning the s

Page 9

CDB5480UDS893DB5 17recognize the MCU (typically 3 seconds), and then select "OK."Figure 11. Connect to the CDB board WindowAt this point, t

Page 10

CDB5480U18 DS893DB52.4.2 CS5480 Serial Port Config ItemIn the Connect menu, the CS5480 Serial Port Config item allows the user to select different typ

Page 11

CDB5480UDS893DB5 19To select SPI communications, position jumper J16 to the SSEL to SPI position and select SPI in theSerial Port Selection window. Se

Page 12

CDB5480U2 DS893DB5 IMPORTANT SAFETY INSTRUCTIONS Read and follow all safety instructions prior to using this demonstration board. This Engineering Ev

Page 13

CDB5480U20 DS893DB52.5 System MenuThe System pull-down provides three options: Setup CS5480, Calibration, and Conversion. Each windowprovides a means

Page 14

CDB5480UDS893DB5 212.5.1 Setup WindowThe evaluation software provides access to the common CS5480's internal registers through the Setupwindow. S

Page 15

CDB5480U22 DS893DB52.5.1.1 Refresh Screen ButtonThe Refresh Screen button will update the contents of the screen by reading all the register values fr

Page 16

CDB5480UDS893DB5 232.5.1.8 Phase CompensationThe Phase Comp Register section is used to make changes to and display the contents of the CS5480'sP

Page 17

CDB5480U24 DS893DB52.5.1.16 V1/V2 Sag, V1/ V2 Swell, and I1/I2 Overcurrent RegistersThe registers for voltage sag, voltage swell, and overcurrent are

Page 18

CDB5480UDS893DB5 25Figure 20. Calibration WindowThe Refresh Screen button will update the contents of the screen by reading all the register values f

Page 19

CDB5480U26 DS893DB52.6.3 Performing CalibrationsAC/DC offset and gain calibrations can be performed on both the voltage and current channels of theCS5

Page 20

CDB5480UDS893DB5 272.7 Conversion WindowThe Conversion window allows the user to see the results of single and continuous conversions and theCS5480 st

Page 21

CDB5480U28 DS893DB5number in the Samples to Average field. The user should stop continuous conversion before leaving thiswindow. The Continuous Conver

Page 22

CDB5480UDS893DB5 292.8 Cirrus Test WindowThe Cirrus Test window provides three options: Test and Debug, ADC Data Collection, and ADC DataCollection to

Page 23

CDB5480UDS893DB5 3TABLE OF CONTENTS1. HARDWARE ...

Page 24

CDB5480U30 DS893DB5The Data Collection window can only be accessed when operating in SPI mode. When UART serialcommunication is enabled, an error win

Page 25

CDB5480UDS893DB5 312.8.1.8 Configuration WindowThe Configuration window allows the user to set up the data collection and analysis parameters. SeeFigu

Page 26

CDB5480U32 DS893DB52.8.1.9 Collecting Data SetsTo collect a sample data set:1. In the Data Collection window, press the Config button to bring up the

Page 27

CDB5480UDS893DB5 33• MINIMUM: indicates the minimum value of the collected data set.Figure 27. Histogram Analysis2.8.1.12 Frequency Domain Informatio

Page 28

CDB5480U34 DS893DB5• FS-PdB: indicates the full-scale to signal Ratio (decibels).Figure 28. FFT Analysis

Page 29

CDB5480UDS893DB5 352.8.1.13 Time Domain InformationThe following controls and indicators are associated with time domain analysis. Time domain data ca

Page 30

CDB5480U36 DS893DB52.8.2 Data Collection to File WindowThe Data Collection to File window allows the user to collect instantaneous voltage and current

Page 31

CDB5480UDS893DB5 372.8.3 Setup and Test WindowThe Setup and Test window allows the user a way to access CS5480 registers and send commands tothe CS548

Page 32

CDB5480U38 DS893DB5APPENDIX A. BILL OF MATERIALSCIRRUS LOGICCDB5480U_REV_D.PLBILL OF MATERIALItem Cirrus P/N RevDescription Qty Reference Designator M

Page 33

CDB5480UDS893DB5 39 CIRRUS LOGICCDB5480U_REV_D.PLBILL OF MATERIALItem Cirrus P/N RevDescription Qty Reference Designator MFG MFG P/N Notes Status36 02

Page 34

CDB5480U4 DS893DB51. HARDWARE1.1 IntroductionThe CDB5480U evaluation board provides a convenient means of evaluating the CS5480 energymeasurement IC.

Page 35

CDB5480U40 DS893DB5APPENDIX B. SCHEMATICSFigure 32. Schematic - Analog Inputs

Page 36

CDB5480UDS893DB5 41 Figure 33. Schematic - CS5480 & SocketREV D202/17/11SCHEM CDB5480U-Z-NPbCS5480+ISOLATIONAlan ZHAAlan ZHA23CHK

Page 37

CDB5480U42 DS893DB5 REV D202/17/11SCHEM CDB5480U-Z-NPb33Alan ZHAAlan ZHAMCU+LCD+USBCHK BY/DATEINC BY/DATEDESCRIPTIONREVECO#SIZE BOFSHEET

Page 38

CDB5480UDS893DB5 43APPENDIX C. LAYER PLOTS Figure 35. Top Silkscreen

Page 39

CDB5480U44 DS893DB5 Figure 36. Top Routing

Page 40

CDB5480UDS893DB5 45 Figure 37. Bottom Routing

Page 41

CDB5480U46 DS893DB5 Figure 38. Solder Paste Mask

Page 42

CDB5480UDS893DB5 47REVISION HISTORYRevision Date ChangesDB1 APR 2011 Initial Release. DB2 DEC 2011 Updated screen shots and circuit diagrams to align

Page 43

CDB5480UDS893DB5 51.3 Analog SectionThe analog section of the CDB5480U is highly configurable. Onboard signal conditioning options for thevoltage and

Page 44

CDB5480U6 DS893DB5The CDB5480U evaluation board provides screw-type terminal (J4) to connect to the high-voltage lineinput. By installing jumpers on J

Page 45

CDB5480UDS893DB5 71.3.2 Current Sensor ConnectionCurrent input options include an external signal (via screw terminals or XLR connectors) or GND. Tabl

Page 46

CDB5480U8 DS893DB51.4 Digital SectionThe digital section contains the microcontroller, USB interface, LCD, optical isolation, JTAG header, resetcircui

Page 47

CDB5480UDS893DB5 91.4.2 Interface to MicrocontrollerInterface headers J17 and J19 are provided to allow the CDB5480U to be connected to an external en